APFC CONTROL PANEL
APFC CONTROL PANEL
Specifications of Single Phase APFC panels
Load | 3KW to 20KW |
Input Voltage | 170V to 270VAC (50Hz) |
No. of CT | 1 |
No. of stages | 4 to 12 |
Minimum KVAR/stage | 0.15 |
Output type | Contactor/SSR |
Display Parameters | Voltage, Current, KW, KVA, KVAR, PF, CT, KWAH, KVAH Polarity reverse, Lag, Lead, Relay on status and under watts |
PF correction range | 0.5 to 0.95-0.99 base correction always more than 0.95 |
Communication port | RS232/RS485 optional |
Salient features of Our APFC panels
Automatic Switching | Our Panels automatically switch capacitor banks in and out of the circuit based on real-time power factor measurements, typically using contactors or thyristors. |
Microprocessor-based Controller | Incorporation of a microprocessor or digital controller for accurate monitoring and adjustment of power factor, which can provide advanced functionalities like data logging and communication on demand |
Power Factor Measurement | Real-time measurement of power factor, voltage, current, and load, allowing for precise adjustments and monitoring. |
Reactive Power Control | The ability to control reactive power supply dynamically to maintain the desired power factor level. |
Harmonic Filtering (Optional) | Advanced APFC panels may include harmonic filters to mitigate harmonic distortion in the system, protecting equipment and improving power quality. |
Alarm and Diagnostics | Built-in alarms for under-voltage, over-voltage, capacitor failure, and other anomalies, along with diagnostic features for troubleshooting. |
User Interface | A user-friendly display/interface that provides real-time readings, status updates, and control parameters, such as LCD or LED panels. |
Communication Interfaces | Capacity for communication via protocols like Modbus, RS-485, or Ethernet for integration with SCADA or building management systems. |
Overcurrent and Short-circuit Protection | Circuit breakers or fuses to protect the capacitor banks and panel from overcurrent and short-circuit conditions. |
Capacitor Bank Protection | Features like discharge resistors, surge protection devices, and reactor coils to protect against inrush currents and transient voltages. |
Smart Control Algorithms | Advanced algorithms for optimal control, such as fuzzy logic or neural network-based systems, which can adapt to changing load conditions. |
Maintenance Indicators | Features that indicate when the capacitors need maintenance, replacements, or have reached the end of their service life. |
Specifications of Three Phase APFC panels
Load | Minimum 10kW |
Input Voltage | 380V-440V |
No. of CT | 3 |
No. of stages | 4 to 12 |
Minimum KVAR/stage | 0.15 |
Output type | Contactor/SSR |
Display Parameters | Voltage, Current, KW, KVA, KVAR, PF, CT, KWAH, KVAH Polarity reverse, Lag, Lead, Relay on status and under watts |
PF correction range | 0.5 to 0.95-0.99 base correction always more than 0.95 |
Communication port | RS232/RS485 optional |